HAPCO, INC. - HEAT WELDING PRODUCTS, HONDA GENERATORS, & HONDA PUMPS HAPCO, INC. offers free covers for Honda Generators
Heat welding products, hot air blowers, Honda generators, & Honda pumps.

category: Generators


















Gillette SENTRY-PRO SP SERIES 18-62 KW

Features
  • HOUSING: Rust proofed steel enclosure with weather and sound protection, easy service access thru large lockable doors.
  • CONTROLLER: Our "SENTINEL-SCOUT" controller is standard equipment on all liquid cooled 1800 RPM gen-sets. We urge you to view this separate features page to learn of the multitude of engine-generator protectors, upgrade to "SENTINEL III", plus our new NFPA style ANNUNCIATOR and the new "SENTINEL IV" controller for tele-communication applications.
  • MICROPROCESSOR: This digital controller monitors normal utility power constantly, and when normal power fails, you have emergency power within 10 seconds. No failure-prone mechanical relays are allowed in this all digital circuitry.
  • CONTROL PANEL: Large and spacious for easier installation connections. Panel door is lockable.
  • INTERIOR AIR DUCTS: Clean fresh air is ducted into the housing. The heat generating items (engine and muffler) are ducted out of the housing. This results in the coolest operating gen-set, available.
  • MUFFLER: Mufflers are used for additional silencing. Exhaust outlet is directed straight up for better safety. Critical and residential mufflers are available as an option, for even more exhaust silencing.
  • AUTOMATIC TRANSFER SWITCH (SUPPLEMENTAL EQUIPMENT): Designed to automatically switch failed utility power out and emergency generator power in, and connect to your loads. This electrically operated, mechanically held switch is UL-1008 certified and has the following features: Engine automatic exerciser, will start and run your gen-set once per week, time delay to start (avoids nuisance starts with common power glitches), time delay for engine cool down before final stop, LED annunciator lights mounted on ATS front cover for showing normal power or emergency power in use, NEMA 1 metal enclosure (for inside installation) or NEMA-3R enclosure (for outdoor installations), and 100 thru 1200 Amp capacity at 240 Volts, 1 phase, or 208, 220, 240, and 480 Volts, 3 phase to match most incoming utility power. The automatic transfer switch is a separate part of the Sentry-Pro standby package, and it is sold separately due to the many choices of different styles and designs of ATS Systems, available to our customers.


Gillette SENTRY-PRO SP SERIES 85-125KW

Features
  • HOUSING: Rust proofed steel enclosure with weather and sound protection, easy service access thru large lockable doors.
  • CONTROLLER: Our "SENTINEL-SCOUT" controller is standard equipment on all liquid cooled 1800 RPM gen-sets. We urge you to view this separate features page to learn of the multitude of engine-generator protectors, upgrade to "SENTINEL III", plus our new NFPA style ANNUNCIATOR and the new "SENTINEL IV" controller for tele-communication applications.
  • MICROPROCESSOR: This digital controller monitors normal utility power constantly, and when normal power fails, you have emergency power within 10 seconds. No failure-prone mechanical relays are allowed in this all digital circuitry.
  • CONTROL PANEL: Large and spacious for easier installation connections. Panel door is lockable.
  • INTERIOR AIR DUCTS: Clean fresh air is ducted into the housing. The heat generating items (engine and muffler) are ducted out of the housing. This results in the coolest operating gen-set, available.
  • MUFFLER: Mufflers are used for additional silencing. Exhaust outlet is directed straight up for better safety. Critical and residential mufflers are available as an option, for even more exhaust silencing.
  • AUTOMATIC TRANSFER SWITCH (SUPPLEMENTAL EQUIPMENT): Designed to automatically switch failed utility power out and emergency generator power in, and connect to your loads. This electrically operated, mechanically held switch is UL-1008 certified and has the following features: Engine automatic exerciser, will start and run your gen-set once per week, time delay to start (avoids nuisance starts with common power glitches), time delay for engine cool down before final stop, LED annunciator lights mounted on ATS front cover for showing normal power or emergency power in use, NEMA 1 metal enclosure (for inside installation) or NEMA-3R enclosure (for outdoor installations), and 100 thru 1200 Amp capacity at 240 Volts, 1 phase, or 208, 220, 240, and 480 Volts, 3 phase to match most incoming utility power. The automatic transfer switch is a separate part of the Sentry-Pro standby package, and it is sold separately due to the many choices of different styles and designs of ATS Systems, available to our customers.


Gillette SENTRY-PRO SPD SERIES 15-65KW

Features
  • HOUSING: Rust proofed steel enclosure with weather and sound protection, easy service access thru large lockable doors.
  • CONTROLLER: Our "SENTINEL-SCOUT" controller is standard equipment on all liquid cooled 1800 RPM gen-sets. We urge you to view this separate features page to learn of the multitude of engine-generator protectors, upgrade to "SENTINEL III", plus our new NFPA style ANNUNCIATOR and the new "SENTINEL IV" controller for tele-communication applications.
  • MICROPROCESSOR: This digital controller monitors normal utility power constantly, and when normal power fails, you have emergency power within 10 seconds. No failure-prone mechanical relays are allowed in this all digital circuitry.
  • CONTROL PANEL: Large and spacious for easier installation connections. Panel door is lockable.
  • INTERIOR AIR DUCTS: Clean fresh air is ducted into the housing. The heat generating items (engine and muffler) are ducted out of the housing. This results in the coolest operating gen-set, available.
  • MUFFLER: Mufflers are used for additional silencing. Exhaust outlet is directed straight up for better safety. Critical and residential mufflers are available as an option, for even more exhaust silencing.
  • AUTOMATIC TRANSFER SWITCH (SUPPLEMENTAL EQUIPMENT): Designed to automatically switch failed utility power out and emergency generator power in, and connect to your loads. This electrically operated, mechanically held switch is UL-1008 certified and has the following features: Engine automatic exerciser, will start and run your gen-set once per week, time delay to start (avoids nuisance starts with common power glitches), time delay for engine cool down before final stop, LED annunciator lights mounted on ATS front cover for showing normal power or emergency power in use, NEMA 1 metal enclosure (for inside installation) or NEMA-3R enclosure (for outdoor installations), and 100 thru 1200 Amp capacity at 240 Volts, 1 phase, or 208, 220, 240, and 480 Volts, 3 phase to match most incoming utility power. The automatic transfer switch is a separate part of the Sentry-Pro standby package, and it is sold separately due to the many choices of different styles and designs of ATS Systems, available to our customers.


Gillette SENTRY-PRO SPD SERIES 85-165 KW

Features
  • HOUSING: Rust proofed steel enclosure with weather and sound protection, easy service access thru large lockable doors.
  • CONTROLLER: Our "SENTINEL-SCOUT" controller is standard equipment on all liquid cooled 1800 RPM gen-sets. We urge you to view this separate features page to learn of the multitude of engine-generator protectors, upgrade to "SENTINEL III", plus our new NFPA style ANNUNCIATOR and the new "SENTINEL IV" controller for tele-communication applications.
  • MICROPROCESSOR: This digital controller monitors normal utility power constantly, and when normal power fails, you have emergency power within 10 seconds. No failure-prone mechanical relays are allowed in this all digital circuitry.
  • CONTROL PANEL: Large and spacious for easier installation connections. Panel door is lockable.
  • INTERIOR AIR DUCTS: Clean fresh air is ducted into the housing. The heat generating items (engine and muffler) are ducted out of the housing. This results in the coolest operating gen-set, available.
  • MUFFLER: Mufflers are used for additional silencing. Exhaust outlet is directed straight up for better safety. Critical and residential mufflers are available as an option, for even more exhaust silencing.
  • AUTOMATIC TRANSFER SWITCH (SUPPLEMENTAL EQUIPMENT): Designed to automatically switch failed utility power out and emergency generator power in, and connect to your loads. This electrically operated, mechanically held switch is UL-1008 certified and has the following features: Engine automatic exerciser, will start and run your gen-set once per week, time delay to start (avoids nuisance starts with common power glitches), time delay for engine cool down before final stop, LED annunciator lights mounted on ATS front cover for showing normal power or emergency power in use, NEMA 1 metal enclosure (for inside installation) or NEMA-3R enclosure (for outdoor installations), and 100 thru 1200 Amp capacity at 240 Volts, 1 phase, or 208, 220, 240, and 480 Volts, 3 phase to match most incoming utility power. The automatic transfer switch is a separate part of the Sentry-Pro standby package, and it is sold separately due to the many choices of different styles and designs of ATS Systems, available to our customers.






© 2008-2009 HAPCO, INC. ALL RIGHTS RESERVED. | This page rendered in 0.20757 seconds. | Return to top.